EasyManua.ls Logo

Dynon SkyView HDX - Network Setup; Post Installation Checks

Dynon SkyView HDX
374 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SV-KNOB-PANEL Panel Installation
SkyView HDX System Installation Manual - Revision E 5-3
5.2 Electrical Installation
SkyView Network
The SV-KNOB-PANEL has two (2) SkyView Network connections (D9 connectors). Both
connectors are electrically identical and are internally connected. Thus, the SV-KNOB-
PANEL can be installed in the SkyView Network as a “pass-through” device, or “daisy
chained” from one (1) SkyView Network device, through the SV-KNOB-PANEL, to the
next SkyView Network device. The SV-NET-1.5CC is an 18-inch (45.72 cm) SkyView
Network cable that is ideal for such situations. The SV-AP-PANEL receives power (for
operation of the buttons) from SkyView Network. Backlighting of the SV-KNOB-PANEL is
controlled by the SkyView display(s).
5.2.1 Network Setup
As with all other SkyView Network devices, the SV-KNOB-PANEL must be configured
into the SkyView Network:
Go to SETUP MENU > SYSTEM SETUP > SKYVIEW NETWORK SETUP >
CONFIGURE > (right click) > DETECT (button).
The SV-KNOB-PANEL(s) will be listed.
FINISH (button) > EXIT (button).
5.3 Post Installation Checks
Verify the knobs work as expected.
Verify dim commands from SkyView display dim the backlighting of the SV-
KNOB-PANEL.