Appendix A: Maintenance and Troubleshooting
23-16 SkyView HDX System Installation Manual - Revision E
• Ensure that the GPS serial port’s parameters are configured correctly. Go to
the Serial Port Setup Menu (SETUP MENU > SYSTEM SETUP > SERIAL
PORT SETUP > SERIAL PORT # SETUP) and check the input device,
function, baud rate, and output device properties of the port. This menu also
contains serial transmit (TX) and receive (RX) counters. These counters show
activity on the transmit and receive lines of that serial port and can indicate if
the GPS is active on that port. Reference the SV-GPS-2020 Electrical
Installation Section for SV-GPS-2020 serial port settings. Also reference the
RS-232 Serial Devices Section on page 4-13 of this manual if a comprehensive
explanation of SkyView serial connections is necessary.
23.10.6 Engine Sensor Does Not Show Up Onscreen
Make sure the sensor is installed, defined, mapped, and configured according to the
instructions found in Section 10 SV-EMS-220 Engine Monitoring System Installation and
Configuration.