SV-ADSB-472 ADS-B IN Receiver Installation and Configuration
SkyView HDX System Installation Manual - Revision E 14-11
• You may also observe the red LED indicator on the SV-ADSB-472 module to
confirm proper hardware operation:
o Flashing Fast: The SV-ADSB-472 is operating normally, is configured and
communicating with SkyView over a correctly-configured serial port, and is
receiving GPS data from SkyView.
o Flashing Slowly: The SV-ADSB-472 is receiving power and operating
normally, but is not fully communicating with SkyView.
o Off: The SV-ADSB-472 is not receiving power.
o On: The SV-ADSB-472 is receiving power, but is not operating normally.
Cycle power on the SV-ADSB-472 to try to clear this condition. If the
indicator remains On (solid, no blinking), after cycling power, contact Dynon
Avionics Technical Support (contact information can be found at the
beginning of this manual).