AP Servo Installation and Configuration
SkyView HDX System Installation Manual - Revision E 16-7
If the autopilot is engaged when this condition is detected, it will remain engaged.
Set to YES if the optional 5 kΩ resistor is installed across the two (2) terminals of the
Disengage/CWS Button. Set to NO if the resistor is not installed. Default is NO.
To set the broken line detection mode:
1. Go to the Enable Broken Line Detect Adjust Page (SETUP MENU > AUTOPILOT
SETUP > DISENGAGE BUTTON > ENABLE BROKEN LINE DETECT).
2. Set to YES or NO.
3. Press ACCEPT to save, or press CANCEL to return to the Disengage Button
Menu.