4. Troubleshooting
45530
11/14
45530
Error: Processor 2
No. 05549
Drive Motor Revolution Count Auto Adjustment error.
Error message release
YES
Condition
NOTE
The suffix number differs depending on the operation which is currently processed.
Diagnosis
NOTE
To access the wiring diagrams, click Wiring diagrams in Bookmarks.
Suffix number Condition
- When Drive Motor Revolution Count Auto Adjustment was performed in Functions of Drive Motor
Revolution Count Setting, the system could not adjust it normally.
Suffix number Condition
00001 Even though the drive motor revolution count is set to 255, it was smaller than the required count.
00002 Even though the drive motor revolution count is set to 0, it was more than the required count.
Failed part Manual No.
Drive motor 63290
Processor relay PCB
66220
Processor control PCB 66200