4. Troubleshooting
45900
45900
Error message: F replenishment
No. 05914[F]
Temperature and humidity sensor error.
Error message release
YES
Condition
Check Point
Diagnosis
NOTE
To access the wiring diagrams, click Wiring diagrams in Bookmarks.
ERROR No. Condition
00001 The measured environmental temperature is not within the range between 10°C and +60°C.
00002 The measured environmental humidity is not within the range between 0 % and 100 %.
An error occurs when Automatic is selected at Operator Selections Processor Humidity.
If errors occur frequently, water is not refilled when evaporated.
In such cases, select one of the Standard , Low or High, except Automatic, in Operator Selections Processor Humidity.
Then, water is refilled and the system can be used again.
Check the status of the temperature and humidity sensor via Input Check.
35220
Check that there is no dust on the temperature and humidity sensor. 63280
Check that there is no connection failure in the wiring between the temperature and humidity sensor and
processor control PCB.
-
Failed part Manual No.
Temperature and humidity sensor
63280
Processor control PCB 66200
Distributed by: minilablaser.com