11/16
4. Troubleshooting
45900
45900
Error message: F replenishment
No. 05914[F]
Temperature and humidity sensor error.
Error message release
YES
Condition
Check Point
Diagnosis
NOTE
• To access the wiring diagrams, click Wiring diagrams in Bookmarks.
ERROR No. Condition
00001 The measured environmental temperature is not within the range between −10°C and +60°C.
00002 The measured environmental humidity is not within the range between 0 % and 100 %.
• An error occurs when Automatic is selected at Operator Selections → Processor → Humidity.
• If errors occur frequently, water is not refilled when evaporated.
In such cases, select one of the Standard , Low or High, except Automatic, in Operator Selections → Processor → Humidity.
Then, water is refilled and the system can be used again.
Check the status of the temperature and humidity sensor via Input Check.
☞35220
Check that there is no dust on the temperature and humidity sensor. ☞63280
Check that there is no connection failure in the wiring between the temperature and humidity sensor and
processor control PCB.
-
Failed part Manual No.
Temperature and humidity sensor
☞63280
Processor control PCB ☞66200