4. Troubleshooting
46000
46000
Error message: Printer 1
$ Symptoms due to connection failure of wiring/symptoms resulted from blowout of fuse
NOTE
• To access the wiring diagrams, click Wiring diagrams in Bookmarks.
00008
00009
00019
This error may occur if the ARCNET communication status is abnormal.
• Check the ARCNET communication status on the Version Check display.
☞35500
• Check the ARCNET communication path.
☞50520
• For details about the diagnosis of ARCNET communication error, see
☞35940.
00022 Confirm the wire connection between the printer control PCB (J/P212) ↔ and the laser control PCB (J/P1520).
• Failure in the laser control PCB
☞66010
• Failure in the printer control PCB
☞66000
00024 • The above errors may occur if problems occur with the software.
If this error still appears after performing the following countermeasure, get the log data.
☞31110
• Check the ARCNET communication status on the Version Check display.
☞35500
• Check the ARCNET communication path.
☞50520
• For details about the diagnosis of ARCNET communication error, see ☞35940.
Symptoms due to the wiring connection failure Symptoms of fuse blowout
☞4202 −−
Suffix number (bit) Countermeasure