EasyManua.ls Logo

GE Multilin F650 - Page 765

GE Multilin F650
1046 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX A: LOGIC OPERANDS A.1 OPERANDS - F650 - MODEL FX - GX
GEK-106310-AF F650 DIGITAL BAY CONTROLLER A-25
Overfrequency
OVERFREQ1 BLOCK Overfrequency element block Group 1
OVERFREQ1 PKP Overfrequency element pickup Group 1
OVERFREQ1 OP Overfrequency element operation Group 1
OVERFREQ2 BLOCK Overfrequency element block Group 2
OVERFREQ2 PKP Overfrequency element pickup Group 2
OVERFREQ2 OP Overfrequency element operation Group 2
OVERFREQ3 BLOCK Overfrequency element block Group 3
OVERFREQ3 PKP Overfrequency element pickup Group 3
OVERFREQ3 OP Overfrequency element operation Group 3
Underfrequency
UNDERFREQ1 BLOCK Underfrequency element block Group 1
UNDERFREQ1 PKP Underfrequency element pickup Group 1
UNDERFREQ1 OP Underfrequency element operation Group 1
UNDERFREQ2 BLOCK Underfrequency element block Group 2
UNDERFREQ2 PKP Underfrequency element pickup Group 2
UNDERFREQ2 OP Underfrequency element operation Group 2
UNDERFREQ3 BLOCK Underfrequency element block Group 3
UNDERFREQ3 PKP Underfrequency element pickup Group 3
UNDERFREQ3 OP Underfrequency element operation Group 3
Frequency rate of change
FREQ RATE1 BLOCK Frequency rate of change element block Group 1
FREQ RATE1 PKP Frequency rate of change element pickup Group 1
FREQ RATE1 OP Frequency rate of change element operation Group 1
FREQ RATE2 BLOCK Frequency rate of change element block Group 2
FREQ RATE2 PKP Frequency rate of change element pickup Group 2
FREQ RATE2 OP Frequency rate of change element operation Group 2
FREQ RATE3 BLOCK Frequency rate of change element block Group 3
FREQ RATE3 PKP Frequency rate of change element pickup Group 3
FREQ RATE3 OP Frequency rate of change element operation Group 3
Broken Conductor
BROKEN CONDUCT1 BLK Broken conductor block Group 1
BROKEN CONDUCT1 PKP Broken conductor element Pickup Group 1
BROKEN CONDUCT1 OP Broken conductor element operation Group 1
BROKEN CONDUCT2 BLK Broken conductor block Group 2
BROKEN CONDUCT2 PKP Broken conductor element Pickup Group 2
BROKEN CONDUCT2 OP Broken conductor element operation Group 2
BROKEN CONDUCT3 BLK Broken conductor block Group 3
BROKEN CONDUCT3 PKP Broken conductor element Pickup Group 3
BROKEN CONDUCT3 OP
Broken conductor element operation Group 3
OPERANDS - F650 - MODEL FX - GX
Internal System Status

Table of Contents