Table 46. SMART ASC/ASCQ error codes and messages (continued)
ASC ASCQ Description
3D 00 INVALID BITS IN IDENTIFY MESSAGE
3E 00 LOGICAL UNIT HAS NOT SELF-CONFIGURED YET
3E 01 LOGICAL UNIT FAILURE
3E 02 TIMEOUT ON LOGICAL UNIT
3E 03 LOGICAL UNIT FAILED SELF-TEST
3E 04 LOGICAL UNIT UNABLE TO UPDATE SELF-TEST LOG
3F 00 TARGET OPERATING CONDITIONS HAVE CHANGED
3F 01 MICROCODE HAS BEEN CHANGED
3F 02 CHANGED OPERATING DEFINITION
3F 03 INQUIRY DATA HAS CHANGED
3F 04 COMPONENT DEVICE ATTACHED
3F 05 DEVICE IDENTIFIER CHANGED
3F 06 REDUNDANCY GROUP CREATED OR MODIFIED
3F 07 REDUNDANCY GROUP DELETED
3F 08 SPARE CREATED OR MODIFIED
3F 09 SPARE DELETED
3F 0A VOLUME SET CREATED OR MODIFIED
3F 0B VOLUME SET DELETED
3F 0C VOLUME SET DEASSIGNED
3F 0D VOLUME SET REASSIGNED
3F 0E REPORTED LUNS DATA HAS CHANGED
3F 0F ECHO BUFFER OVERWRITTEN
3F 10 MEDIUM LOADABLE
3F 11 MEDIUM AUXILIARY MEMORY ACCESSIBLE
3F 12 ISCSI IP ADDRESS ADDED
3F 13 ISCSI IP ADDRESS REMOVED
3F 14 ISCSI IP ADDRESS CHANGED
40 00 RAM FAILURE
40 NN DIAGNOSTIC FAILURE ON COMPONENT NN
41 00 DATA PATH FAILURE
42 00 POWER-ON OR SELF-TEST FAILURE
43 00 MESSAGE ERROR
44 00 INTERNAL TARGET FAILURE
44 71 ATA DEVICE FAILED SET FEATURES
45 00 SELECT OR RESELECT FAILURE
46 00 UNSUCCESSFUL SOFT RESET
47 00 SCSI PARITY ERROR
47 01 DATA PHASE CRC ERROR DETECTED
47 02 SCSI PARITY ERROR DETECTED DURING ST DATA PHASE
47 03 INFORMATION UNIT IUCRC ERROR DETECTED
112 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI