Table 46. SMART ASC/ASCQ error codes and messages (continued)
ASC ASCQ Description
47 04 ASYNCHRONOUS INFORMATION PROTECTION ERROR DETECTED
47 05 PROTOCOL SERVICE CRC ERROR
47 06 PHY TEST FUNCTION IN PROGRESS
47 7F SOME COMMANDS CLEARED BY ISCSI PROTOCOL EVENT
48 00 INITIATOR DETECTED ERROR MESSAGE RECEIVED
49 00 INVALID MESSAGE ERROR
4A 00 COMMAND PHASE ERROR
4B 00 DATA PHASE ERROR
4B 01 INVALID TARGET PORT TRANSFER TAG RECEIVED
4B 02 TOO MUCH WRITE DATA
4B 03 ACK/NAK TIMEOUT
4B 04 NAK RECEIVED
4B 05 DATA OFFSET ERROR
4B 06 INITIATOR RESPONSE TIMEOUT
4B 07 CONNECTION LOST
4C 00 LOGICAL UNIT FAILED SELF-CONFIGURATION
4D NN TAGGED OVERLAPPED COMMANDS (NN = TASK TAG)
4E 00 OVERLAPPED COMMANDS ATTEMPTED
53 00 MEDIA LOAD OR EJECT FAILED
53 02 MEDIUM REMOVAL PREVENTED
55 01 SYSTEM BUFFER FULL
55 02 INSUFFICIENT RESERVATION RESOURCES
55 03 INSUFFICIENT RESOURCES
55 04 INSUFFICIENT REGISTRATION RESOURCES
55 05 INSUFFICIENT ACCESS CONTROL RESOURCES
55 06 AUXILIARY MEMORY OUT OF SPACE
55 0B INSUFFICIENT POWER FOR OPERATION
5A 00 OPERATOR REQUEST OR STATE CHANGE INPUT
5A 01 OPERATOR MEDIUM REMOVAL REQUEST
5A 02 OPERATOR SELECTED WRITE PROTECT
5A 03 OPERATOR SELECTED WRITE PERMIT
5B 00 LOG EXCEPTION
5B 01 THRESHOLD CONDITION MET
5B 02 LOG COUNTER AT MAXIMUM
5B 03 LOG LIST CODES EXHAUSTED
5C 00 RPL STATUS CHANGE
5C 01 SPINDLES SYNCHRONIZED
5C 02 SPINDLES NOT SYNCHRONIZED
5D 00 FAILURE PREDICTION THRESHOLD EXCEEDED
5D 05 HARDWARE IMPENDING FAILURE HARD DISK DRIVE ERROR
Chapter 4. File module 113

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals