EasyManuals Logo

IBM Storwize V7000 Unified Problem Determination Guide

IBM Storwize V7000 Unified
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
Table 46. SMART ASC/ASCQ error codes and messages (continued)
ASC ASCQ Description
5D 10 HARDWARE IMPENDING FAILURE GENERAL HARD DRIVE
FAILURE
5D 11 HARDWARE IMPENDING FAILURE DRIVE ERROR RATE TOO HIGH
5D 12 HARDWARE IMPENDING FAILURE DATA ERROR RATE TOO HIGH
5D 13 HARDWARE IMPENDING FAILURE SEEK ERROR RATE TOO HIGH
5D 14 HARDWARE IMPENDING FAILURE TOO MANY BLOCK REASSIGNS
5D 15 HARDWARE IMPENDING FAILURE ACCESS TIMES TOO HIGH
5D 16 HARDWARE IMPENDING FAILURE START UNIT TIMES TOO HIGH
5D 17 HARDWARE IMPENDING FAILURE CHANNEL PARAMETRICS
5D 18 HARDWARE IMPENDING FAILURE CONTROLLER DETECTED
5D 19 HARDWARE IMPENDING FAILURE THROUGHPUT PERFORMANCE
5D 1A HARDWARE IMPENDING FAILURE SEEK TIME PERFORMANCE
5D 1B HARDWARE IMPENDING FAILURE SPIN-UP RETRY COUNT
5D 1C HARDWARE IMPENDING FAILURE DRIVE CALIBRATION RETRY
COUNT
5D 20 CONTROLLER IMPENDING FAILURE GENERAL HARD DRIVE
FAILURE
5D 21 CONTROLLER IMPENDING FAILURE DRIVE ERROR RATE TOO
HIGH
5D 22 CONTROLLER IMPENDING FAILURE DATA ERROR RATE TOO
HIGH
5D 23 CONTROLLER IMPENDING FAILURE SEEK ERROR RATE TOO
HIGH
5D 24 CONTROLLER IMPENDING FAILURE TOO MANY BLOCK
REASSIGNS
5D 25 CONTROLLER IMPENDING FAILURE ACCESS TIMES TOO HIGH
5D 26 CONTROLLER IMPENDING FAILURE START UNIT TIMES TOO
HIGH
5D 27 CONTROLLER IMPENDING FAILURE CHANNEL PARAMETRICS
5D 28 CONTROLLER IMPENDING FAILURE CONTROLLER DETECTED
5D 29 CONTROLLER IMPENDING FAILURE THROUGHPUT
PERFORMANCE
5D 2A CONTROLLER IMPENDING FAILURE SEEK TIME PERFORMANCE
5D 2B CONTROLLER IMPENDING FAILURE SPIN-UP RETRY COUNT
5D 2C CONTROLLER IMPENDING FAILURE DRIVE CALIBRATION RETRY
COUNT
5D 30 DATA CHANNEL IMPENDING FAILURE GENERAL HARD DRIVE
FAILURE
5D 31 DATA CHANNEL IMPENDING FAILURE DRIVE ERROR RATE TOO
HIGH
5D 32 DATA CHANNEL IMPENDING FAILURE DATA ERROR RATE TOO
HIGH
5D 33 DATA CHANNEL IMPENDING FAILURE SEEK ERROR RATE TOO
HIGH
114 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals