EasyManuals Logo

IBM Storwize V7000 Unified Problem Determination Guide

IBM Storwize V7000 Unified
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
environment variable. If you see the following error message when running the
command, wait until the initialization has completed before running
setcluster again:
IBM SONAS management service is starting up
EFSSG0654I The Management Service is starting up.
After you run the startmgtsrv command, the system displays information that
is similar to the following example:
[yourlogon@yourmachine.mgmt002st001 ~]# startmgtsrv
Other node is reachable and its management state is active.
Are you sure? (Y/N)Y
EFSSG0717I Takeover initiated by root - this may take a few minutes
EFSSG0544I Takeover of the management functions from the active
node was successful
Results
Once complete, the file module that previously hosted the active management
node role now hosts the passive management node role. The file module that
previously hosted the passive management node role now hosts the active
management node role.
Performing management node role failover procedures for failure
conditions
Use this topic to isolate and perform file module failover for failed conditions.
About this task
“Failed conditions” exist when the active management node has failed and is not
responding. This failure is exposed by the inability to access the file module, run
CLI commands, and/or access the GUI.
Note: If the management IP is accessible and you can establish an SSH connection
and run CLI tasks, do not perform a management failover. Refer to .
Complete the following procedure to address this issue.
Important: You need a CLI user with SystemAdmin privilege to perform this
procedure. Performing this procedure does not repair a problem that caused the
current system condition. This procedure provides for system access and
troubleshooting to restart the management services or to failover the management
service from a failed file module to the passive management node on the other file
module. Once you complete this procedure, follow the appropriate troubleshooting
documentation to isolate and repair the core problem that caused this condition.
Procedure
1. Attempt to open an SSH connection to the service IP of the file module with
the active management node role. Refer to . Was the connection successful?
v Yes - proceed to step 2
v No - proceed to step 5 on page 186
2. If the connection is successful, verify that the management service is not
running by executing the CLI command lsnode and then reviewing the output.
v If the system responds with output for the lsnode command, then the
management services are already running. If you still cannot access the GUI,
refer to . If the GUI is accessible, then the management services are properly
running on the active management node and no failover is needed. If you
Chapter 4. File module 185

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI