Table 120. Upgrade error codes and recommended actions (continued)
Error
Code Explanation Action
01B8 Failed to query status of Storwize
V7000 nodes by using the svcinfo
lsnode command.
See Chapter 5, “Control enclosure,” on
page 203.
01B9 Failed to check the Storwize V7000
version.
This could be caused by a number of
issues. Check Monitoring > Events under
both the block tab and the file tab on the
management GUI for an event that could
have caused this error and follow the
recommended action. If there is no
obvious event that could have caused
this error, refer to “Ethernet connectivity
from file modules to the control
enclosure” on page 68.
01BA Unable to verify the correct
software version.
1. Check the health of the storage
controllers.
2. Contact IBM Remote Technical
Support.
01BC Check the health of storage
controllers.
Contact IBM Remote Technical Support.
01BD Unable to update software
repository.
1. Ensure that the system is not under a
heavy load. Restart the upgrade.
2. Contact IBM Remote Technical
Support.
01BE Unable to distribute upgrade
callbacks.
1. Check on health of the cluster using
lshealth.
2. Contact IBM Remote Technical
Support.
01BF Upgrade callback failed
1. Contact your customer advocate.
Upgrade callbacks are custom steps
placed on a system before the start of
upgrade.
2. Contact IBM Remote Technical
Support.
01C0 Asynchronous replication is
running. Stop asynchronous
replication and continue with the
upgrade.
1. Stop asynchronous replication by
typing stoprepl gpfs0 --kill.
Asynchronous replication is
considered active if in RUNNING or
KILLING state.
2. Contact IBM Remote Technical
Support.
01C1 Asynchronous replication failed to
stop. Stop asynchronous replication
and continue with the upgrade.
1. Stop asynchronous replication by
typing stoprepl gpfs0 --kill.
Asynchronous replication is
considered active if in RUNNING or
KILLING state.
2. Contact IBM Remote Technical
Support.
422 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI