EasyManua.ls Logo

Leibinger JET3 up - Digital Outputs; Figure 63 Assign States and Messages to Digital Outputs

Leibinger JET3 up
412 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Group 8 Job Editor Page 155
JET3up Release R1.06
7.3.3.2 Digital Outputs
With the tab <Outputs> you can assign printer states and messages to the
available outputs.
ATTENTION
Standardly the outputs 1-3 are already predefined!
Output 1 (X3.1) = Error
Output 2 (X3.2) = Warning
Output 3 (X3.3) = Printer busy
E.g.: The output X3.9 (Pin No. 9 of interface X3) should be assigned to the
message “Product counter reached value”.
Proceeding:
Press on the tab <Outputs> (2) to select the tab.
Press on the arrow key of the drop-down list of the output [X3.9] (3). The drop-
down list provides a list of events/signals for selection.
Now select the required event/signal.
INFORMATION
Please see chapter 5.5.5 Interface X3 - Digital outputs for details
about digital outputs
Figure 63 Assign states and messages to digital outputs
1 – Dialog box <I/O Settings>
3 – Drop-down list <X3.9>
2 – Tab <Outputs>
4 – Pin designation
2
4
3
1

Table of Contents