Page 62 Transport/Start up Group 5
Release R1.06 JET3up
5.5.3.2 Mechanical installation
ATTENTION
For the mechanical installation of the shaft encoder you have to pay
attention in any case that the encoder is protected against axial and
radial strain during the mounting and the continuous operation. For
this a rubber gaiter or a plastic coupling is used.
If the conditions allow it, the shaft encoder can be also adapted to a production line
with a friction wheel.
ATTENTION
Risk of injury!
The shaft encoder has to be installed or mounted that no risks of
injury can occur!
5.5.4 Interface X4 - Digital inputs
19 inputs for special functions are available whereof the connections of 6 inputs can
be freely selected.
Plug assignment:
Pin connection:
Pin
Designation
Pin
Designation
1
+Reset Counter
14
+24V
(1)
2
+Increment Counter
15
GND Reset Counter /
Increment Counter
3
+Jobselect 0
16
+Jobselect 1
4
+Jobselect 2
17
+Jobselect 3
5
+Jobselect 4
18
+Jobselect 5
6
+Jobselect 6
19
+Jobselect 7
7
+Jobselect 8
20
+Jobselect 9
8 GND Jobselect 0-9 21 GND Input 0-5
9
+Input 0
22
+Input 1
10
+Input 2
23
+Input 3
11
+Input 4
24
+Input 5
12
+Power ON
25
GND Power On
13
GND 24V

Table of Contents