Group 4 Accident prevention Page 37
JET3up Release R1.06
4.2 Electrical connection values
Input voltage (voltage range):
100 - 240 V AC, 50-60 Hz
Current consumption:
max. 0,56 A (peak) at 100 V AC
max. 0,25 A (peak) at 240 V AC
Power consumption:
typ. 20 W at 100 V AC
typ. 20 W at 240 V AC
4.3 Ambient conditions
Temperature range:
+ 5° C to + 45° C (no rapid change of temperature)
Relative humidity:
max. 90 % relative humidity (non-condensating)
4.4 Interfaces, Inputs, Outputs
Product sensor input:
NPN/PNP 24V
Incremental encoder input:
TTL 5V, HTL 24V, RS422 5V
Inputs:
6 digitals, free selectable
10 inputs for ext. job selection
Outputs:
8 digitals, e.g. for alarm, re-filling, etc.
Interfaces:
Ethernet (Industry standard M12D)
Serial Interface (V24/RS232) up to 115.200 Baud
USB
4.5 Performance parameter
Printing capacity:
Character height: approx.
min.: 0,8 mm
max.:16 mm
Depending on font, distance of head, nozzle diameter,
ink, product surface and type of print head
Up to 3200 characters/sec.
Printing speed:
Up to 6,6 m/sec (10 cpi)