Page 180 Job Editor Group 8
Release R1.06 JET3up
7.4.6.1 Export <Print History Protocol>
The displayed information can be exported to an external memory device like an
USB-
stick or a network storage device. There is always the complete information
about each print job exported.
Important
In order to store the data on a network storage device the network path
settings have to be configured. Please see chapter 7.3.1.7 Network ID
for details.
The socket for the USB stick is located on the
reverse side of the printer.
Please see chapter 5.5 Interfaces for details.
Proceeding:
Configure the <Network ID> of the printer in the <Basic settings> (1)
and/or
Plug an USB-Stick into the USB-socket of the device (2).
Press the button <Export> (3).
If there is a network ID configured and the network connection is activated a
confirmation prompt will pop up asking whether the data shall be saved to the
network storage device (4)
. If this message is confirmed the information will be
stored on the network storage device. If the message is not confirmed it is
checked whether an USB stick is availabe. If no USB stick is avaibe a respective
message box pops up (5)
. With an USB stick inserted the information is stored
to the USB stick.
When saving is finished a confirmation messages pop up (6)
The message has to be confirmed with the <OK> button (7).
The files are saved in a folder named JET3UP_Log. If this fo
lder does not
already exist it will be created by the <Export> function.
Information
The number of print events that are recorded is limited. The maximum
number of recorded events is 1000. The memory works as a circular
buffer. When the maximum of entries allowed is reached the oldest
entries will be overwritten. Therefor it is recommended exporting the on
a regular basis in order to have a backup. It is possible to activate a
warning message. With the warning activated a message box advising
the user to export the <Print History Protocol> before the oldest entries
are overwritten. Please see chapter 7.3.1.5 Factory Settings for details.