Loading...
Page 170 Job Editor Group 8
Release R1.06 JET3up
7.4.3.2 Ink on/off
With the two buttons <Ink on > (2) and <Ink off > (3) the ink delivery to the
nozzle is turned on or off.
The status of the ink delivery is designated by a
on the accordant button.
This function can be generated also „remote-controlled“ by an electronical contact
(see also the informations in the following chapter).
7.4.3.3 Extern Ink on/off
During cleaning works at the print head it can be helpful (e.g. in case of a long
umbilical) that the ink delivery can be turned on/off externally. The JET3up
requires
impulses for the control. This can be reached with a bridge between pin 9 and 14
and a switch contact (push button) at the pins 21 and 13 of the I/O interface X4.
Example:
First impulse = switches off the ink delivery
Second impulse = switches on again the ink delivery
Diagram/Plug assignment:
The signal which is pending at the interface is only analyzed by the JET3up if the
function <Extern Ink on/off active> (4) is turned on.
If the function is activated, it is shown by a
on the display.
7.4.3.4 Piezo test and charge test
INFORMATION
You will find further information in the separate document
Service manual!