Page 286 Job Editor Group 8
Release R1.06 JET3up
8.5.3.5 Speed dependent output
In dependence of a pre-adjusted speed limit, this special output signal switches ON
or OFF. The setting for the output can be found in the main window under
Settings
► I/O Settings ► Outputs. The speed dependent outpu
t can be assigned to any
available output.
Function:
The assigned output switches to high level once the set speed is
reached or exceeded. The assigned output switches back to low level
when the speed falls 10% below the set speed.
Figure 157 Speed dependent output – Settings/diagram
Assigning the speed dependent
output function to an available
output
Basic function diagram
Please see example on the next page!