Page 174 Job Editor Group 8
Release R1.06 JET3up
7.4.4.2 Mix only ink/sovent
With the two buttons <Mix only Ink > (1) and <Mix only Solvent > (2) only ink
or solvent can be supplied to the hydraulic circuit.
These functions allow to set the viscosity of the ink fast to a lower or higher value.
The execution of addition of the selected medium is displayed by an accordant
message (3).
With the button <Stop> (4) the process will be finished.
By adding solvent the ink can be diluted too strong. Therefore this
function should only be carried out by qualified personnel.
Figure 75 Add only ink/solvent
4 – Message <Adding solvent only>
3 – Message <Adding ink only>