Group 8 Job Editor Page 281
JET3up Release R1.06
Please see also chapter 12.3 Encoder guidelines and “hot-plugging” of
external devices for details about encoders.
8.5.3.1 Encoder source - StrokeGo-source
There are three options in order to define the <StrokeGo> source:
Internal: If this function is activated, the signal is generated by the printer and
needs no external encoder device.
Additionally you have to enter the <Internal speed (intern Speed)> (3).
The internal encoder source is only recommended for constant
printing speeds.
You will find further information regarding this topic in the chapter
Internal speed
If this function is activated signals from an external encoder (e.g. incremental
encoder) are required. The encoder has to be connected to the interface X1 of
the LEIBINGER JET3up.
Additionally you have to define the <Encoder/Direction> (4) and the
<Resolution> (5).
Sensor measurement: If this function is activated the JET3up printer expects 2
sensor signals in order to calculate the required printing speed. The
<StrokeGo> signals are generated on the basis of the calculated speed.
Figure 155 StrokeGo-source /Encoder source
1 – Check box <Encoder source int.>
3 – Display field <Internal speed>
2 – Check box <Encoder source ext.>
4 – Check box <Sensor Measurement>