Group 8 Job Editor Page 357
JET3up Release R1.06
8.7.5.3.4 Mailing Printout
See figure 181
If there are <Mailing> objects in
the current print job you will see the placeholders
in the print preview of the main window (1) as long as there was no print-
out. If
you press the green <Print Start> button (2)
the database settings dialog box will
be displayed (3).
You can identify the data set the last print-out made was from (6)
and you can set
from which data sets shall be printed by defining the first record to be printed (4)
and the last one (5).
It is possible to print fields from already printed data sets once again. That means
the setting in the <StartAt> display field (4) do not depend on the
<Last printed
database record> (5).
You can confirm the settings by pressing the <OK> button (8)
. Pressing the
<Cancel> button (7) will close the dialog box without any changes and the
red
<Print Stop> button (9) will remain switched on.
If the settings are confirmed the dialog box will close and the <Print Start>
button
will switch on (11)
. You will see the content of the fields of the first data set
selected for print-out in the print preview of the main window (10)
. With the next
PrintGo signal the first data set will be printed. With each following PrintGo signal
the respectively next data set is printed.
Which field of a data set is printed has to be defined in the object settings
of the
<Mailing> object. Each field to be printed has to be assigned to a <Mailing>
Object. You can only assign one filed of a data set to one <Mailing> object.
With
the parameter <Wildcard>
you can define how many character of one field shall
be used. The
parameter indicates the number of used characters on the basis of a
left-to right reading direction.
INFORMATION
With the <Wildcard> settings. See <Example Field number> and
Figure 179 for details.
If a PrintGo signal is received after the last data set was printed an error message
will be displayed (12). The message has to confirmed and the printer is set to
<Print Stop> (9).
For a new printing sequence you will have to press the green <Print Start> (2)
button again and specify the data sets to be printed.