Settings for @Remote Service
D0AP/D0C4/D0C5/D0C6/M0BQ/M0D1 2-140 SM
Make sure to shut down and reboot the machine once before printing the SMC. Otherwise,
the latest settings may not be collected when the SMC is printed.
• SP5-811-003 (Machine No. Setting: ID2 Code Display)
Sets the ID-2 code used to identify the @remote device at installation.
• SP5-816-062 (Remote Service: Use Proxy)
0: Not use
1: Use
This SP setting determines if the proxy server is used when the machine communicates
with the service center.
• SP5-816-063 (Remote Service: Proxy server IP address)
This SP sets the address of the proxy server used for communication between the RCG
device and the gateway. Use this SP to set up or display the customer proxy server
address.
The address is necessary to set up the embedded RCG-N.
The address display is limited to 127 characters. Characters beyond the 127 characters
are ignored.
This address is customer information and is not printed in the SMC report.
• SP5-816-064 (Remote Service: Proxy server Port number)
This SP sets the port number of the proxy server used for communication between the
embedded RCG-N and the gateway. This setting is necessary to set up the embedded RC
Gate-N.
This port number is customer information and is not printed in the SMC report.
• SP5-816-065 (Remote Service: Proxy User ID)
This SP sets the HTTP proxy certification username.
The length of the name is limited to 31 characters. Any character beyond the 31st
character is ignored.
This name is customer information and is not printed in the SMC report.
• SP5-816-066 (Remote Service: Proxy Password)
This SP sets the HTTP proxy certification password.
The length of the password is limited to 31 characters. Any character beyond the 31st
character is ignored.
This name is customer information and is not printed in the SMC report.
2.29.2 EXECUTE THE @REMOTE SETTINGS
1. Enter the SP mode.
2. Using SP5-816-202, input the request number which you have obtained from @Remote
Center GUI, and then enter [OK].
3. Confirm the request number, and then execute SP5-816-203.
4. Check the confirmation result using SP5-816-204.