Settings for @Remote Service
D0AP/D0C4/D0C5/D0C6/M0BQ/M0D1 2-142 SM
Value Meaning Solution/ Workaround
24 Low power supply current
25 unplugged modem
26 Busy line
8. Exit the SP mode.
SP5-816-208 Error Codes
Caused by Operation Error, Incorrect Setting
Code Meaning Solution/ Workaround
-12002 An Inquiry or registration attempted without
acquiring a request number.
Obtain a Request Number before
inquiry or registration.
-12003 Attempted registration without execution of a
confirmation and no previous registration.
Perform Confirmation before
attempting registration.
-12004 Attempted setting with illegal entries for
certification and ID2.
Check ID2 of the machine.
-12005 @Remote communication is prohibited. The
device has an Embedded RC gate-related
problem.
Make sure that "Remote Service" in
User Too ls is set to "Do not prohibit".
-12006 A confirmation request was made after the
confirmation had been already completed.
Execute registration.
-12007 The request number used at registration was
different from the one used at confirmation.
Check the request number.
-12008 Update certification failed because mainframe
was in use.
Check the machine status. If the
machine is in use, try again later.
-12009 The ID2 in the NVRAM does not match the ID2
in the individual certification.
Check ID2 of the machine.
-12010 The certification area is not initialized. Initialize the certification area.
Error Caused by Response from GW URL
Code Meaning Solution/ Workaround
-2385 Other error
-2387 Not supported at the Service Center
-2389 Database out of service
-2390 Program out of service
-2391 Two registrations for the same machine Check the registration condition of the
machine
-2392 Parameter error
-2393 External RCG not managed
-2394 Machine not managed
-2395 Box ID for external RCG is illegal.