Run Up / Coast Down Module
Displaying Acquired Data
Figure 7 - 20.
An Example Waterfall Plot.
speed at which active spectrum was captured
return to Waterfall Setup screen to change options and process new waterfall
spectra
frequency and magnitude at cursor position on active spectrum
initiate Display Setup screen for quick re-adjustment of how spectra appear in the
waterfall plot
waterfall “display status” area