Parameter list
9836 3123 01 369 (428)
Parameter
number
Parameter name
Description
Default value
T224
Events
The event-sound configuration.
T230
CW pressed
Defines the function of function button when ring is in CW position.
Available functions are described in chapter.
For SL-drive:97
(Toggle CW
CCW)
Otherwise: Off
T231
CCW pressed
Defines the function of the function button when ring is in CCW
position. Available functions are described in chapter.
For SL-drive:97
(Toggle CW
CCW)
Otherwise: Off
T232
CW single push
Defines the function of function button single push when ring is in CW
position. Available functions are described in chapter.
Off
T233
CCW single push
Defines the function of function button single push when ring is in
CCW position. Available functions are described in chapter.
Off
T234
CW double push
Defines the function of function button double push when ring is in CW
position. Available functions are described in chapter.
Off
T235
CCW double push
Defines the function of function button double push when ring is in
CCW position. Available functions are described in chapter.
Off
T236
Push detection
interval
Defines the maximum time that may elapse from button down to button
up for a push to be detected. Range: 250 to 1000 ms.
300
T237
Next push interval
Defines the maximum time that may elapse from successful detection of
a push for a new push to be detected. Range: 250 to 1000 ms.
300
T240
Events
The blue LED is used to highlight events similar to the relays of the
controller. The blue LED may be set to highlight several events. Use the
add key to add events and set duration. Remove events with the remove
key. Available functions are described in chapter.
Off
T250
Illuminator mode
Defines operation mode of illuminator (LED’s in front of the tool and
corresponding relay function). Available selections are off, on, tracking
event and event controlled.
Off
T251
On event
Defines which event (relay function) that is used to turn on illuminator
while operating in “tracking event” or “event controlled” mode. For
available events see 648HDigital I/O and fieldbus items (Blue LED).
Off
T252
Off event
Defines which event (relay function) that is used to turn off illuminator
while operating in “event controlled” mode. For available events see
649HDigital I/O and fieldbus items (Blue LED).
Off
T253
On time
Defines how long illuminator will remain lit, if not turned off by event,
while operating in “tracking event” or “event controlled” mode.
On time period starts to elapse when on event occurs. In case on event
occurs again before on time has elapsed, the on time period will be
restarted.
60

Table of Contents

Other manuals for Atlas Copco Power Focus 3000