Event codes
390 (428) 9836 3123 01
First integer
Second integer
Third integer
Fourth integer
The stage
when the
Multistage
aborted
The event code
Error bits part I
Error bits part II
Dec
Event
Dec
Event
n
Stage n
nnn
No of event that
occurred
1
Multistage aborted
1
Rundown angle max exceeded
2
Rehit
2
Rundown angle min not reached
4
Torque measurement
possible invalid
4
Final torque max exceeded
8
Current limit reached
8
Final angle max exceeded
16
Timeout on end time
shutoff
16
Self tap max exceeded
32
Remove fastener limit
32
Self tap min not reached
64
Drive disabled
64
PVT monitoring max exceeded
128
Transducer lost
128
PVT monitoring min not
reached
256
Transducer short circuit
256
PVT Compensate overflow
512
Transducer corrupt
512
Current monitoring max
exceeded
1024
Sync timeout
1024
Post view torque min not
reached
2048
Dynamic CM Min Tq
2048
Post view torque max exceeded
4096
Dynamic CM Max Tq
4096
Post view torque angle too small
8192
Angle Max mon
8192
Trigger lost
16384
Yield nut off
16384
Torque less than target
32768
Yield too few samples
32768
Tool hot

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals