Event codes
9836 3123 01 391 (428)
This event indicates that the drive was
shut off in the selftap or prevail phase of
the rundown, or the compensate conditions
were not fulfilled.
In the Trace monitor, check the result
and change the settings accordingly.
When the function trigger lost is activated
in the Pset, this event indicates that the
trigger of the tool was released before final
target.
When the function torque lower than
target is activated in the Pset, this event
indicates that the torque result is below
final target. The torque status is NOK even
if the torque result was larger than final
torque min.
For information only.
Note: Check also E128 to see if E129
is issued because the trigger was
released before final target.
Post view torque
shut off
Post view torque conditions were not
fulfilled.
In the Trace monitor, check the result
and change the settings accordingly.
This event code is generated when the tool
is disconnected (logically or physically)
from PF. The event code is also generated
when an attempt to start a disconnected
(logically or physically) tool is done.
Additional parameter information:
First integer parameter: 0=locked during
tightening, 1=locked during loosening,
2=locked during positioning, 3=locked
during motor tuning, 4=locked during
open end tuning.
Second integer parameter 0=Service
denied, 1=service aborted.
A damaged cable can result
in a disconnected tool.
Acknowledge the event.
If the tool has been logically
disconnected, disconnect physically
also.
Note: The tool can be logically
disconnected if the user requests
disconnection or if the open end
settings are modified.
Wrong tool start
input setting
T200 Tool start select source is not
corresponding to the remote start jumper
position.
Acknowledge the event.
Check the wiring of the remote start
connector.
Verify that the tool trigger is not
pressed during hot swap or system
start-up.