Event codes
392 (428) 9836 3123 01
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E133
Tool locked by
Tools Talk
The tool is prohibited via ToolsTalk PF.
Additional parameter information:
First integer parameter: 0=locked during
tightening, 1=locked during loosening,
2=locked during positioning, 3=locked
during motor tuning, 4=locked during
open end tuning.
Second integer parameter 0=Service
denied, 1=service aborted.
Unlock the tool by
- sending an “Enable tool” message via
ToolsTalk PF protocol or
- using digital input Master unlock
tool.
x
E136
Tool locked by
batch OK
This event code is displayed if the tool is
locked by the function P152 Lock at batch
OK.
Additional parameter information:
First integer parameter: 0=locked during
tightening, 1=locked during loosening,
2=locked during positioning, 3=locked
during motor tuning, 4=locked during
open end tuning.
Second integer parameter 0=Service
denied, 1=service aborted.
Unlock the tool by
- using the digital inputs Unlock tool
or Master unlock tool or
- sending an “Enable tool” message on
fieldbus, Open protocol or ToolsTalk
PF protocol.
x
E137
Tool locked by
fieldbus
The tool is locked by fieldbus.
Additional parameter information:
First integer parameter: 0=locked during
tightening, 1=locked during loosening,
2=locked during positioning, 3=locked
during motor tuning, 4=locked during
open end tuning.
Second integer parameter 0=Service
denied, 1=service aborted.
Unlock the tool by
- sending an “Enable tool” message via
fieldbus or
- using the digital input Master unlock
tool.
x
E138
Wrong tool start
input source
It is only possible to start the tool from
selected tool start select source.
Check the setting for T200 Tool start
select source.
E139
Tool locked by
Open protocol
The tool is locked by open protocol.
Additional parameter information:
First integer parameter: 0=locked during
tightening, 1=locked during loosening,
2=locked during positioning, 3=locked
during motor tuning, 4=locked during
open end tuning.
Second integer parameter 0=Service
denied, 1=service aborted.
Unlock the tool by
- sending an “Enable tool” message via
Open protocol or
- using the digital input Master unlock
tool.
x

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals