DES-1210-28/ME Metro Ethernet Managed Switch CLI Reference Guide
32
Restrictions None.
Example usage:
To configure the loopback detection mode to be portabse on the Switch:
DES-1210-28/ME:5# config loopdetect mode portbase
Command: config loopdetect mode portbase
Success!
DES-1210-28/ME:5#
config loopdetect ports
Purpose To configures the loop back detection to be enabled or disabled for
the specific ports on the Switch.
Syntax
config loopdetect ports [<portlist> | all] [enable | disable]
Description
The config loopdetect ports command configures the loop back
detection to be enabled or disabled for the specific ports on the
Switch.
Parameters
<portlist> − A port or range of ports to be configured.
all − All ports settings are to be configured.
[enabled | disabled] − Specifies the loop back detection is enabled or
disabled for the specified ports on the Switch.
Restrictions Only administrator or operate-level users can issue this command.
Example usage:
To enable the loop back detection on the Switch:
DES-1210-28/ME:5# config loopdetect ports all enable
Command: config loopdetect ports all enable
Success!
DES-1210-28/ME:5#
config loopdetect
Purpose To configure the loop back detection interval time and recover time
on the Switch.
Syntax
config loopdetect interval_time <value 1-32767>
lbd_recover_time [0 | <value 60-1000000>]
Description
The config loopdetect command configures the loop back
detection interval time and recover time on the Switch.
Parameters
interval_time <value 1-32767> − Specifies the interval time of loop
back detection. The range is between 1 and 32767 seconds.
lbd_recover_time [0 | <value 60-10000>] Specifies the recover
time of loop back detection on the switch. The range is between 60
and 10000 seconds.
Restrictions Only administrator or operate-level users can issue this command.