DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
165
DGS-3000-26TC:admin#create cfm mep mep1 mepid 1 md op_domain ma op1 direction
inward port 2
Command: create cfm mep mep1 mepid 1 md op_domain ma op1 direction inward port
2
Success.
DGS-3000-26TC:admin#
config cfm mep 16-6
Description
This command is used to configure the parameters of an MEP. An MEP may generate 5 types of
Fault Alarms, as shown below by their priorities from high to low:
• Cross-connect CCM Received: priority 5
• Error CCM Received: priority 4
• Some Remote MEPs Down: priority 3
• Some Remote MEP MAC Status Errors: priority 2
• Some Remote MEP Defect Indications: priority 1
If multiple types of the fault occur on an MEP, only the fault with the highest priority will be alarmed.
Format
config cfm mep [mepname <string 32> | mepid <int 1-8191> md [<string 22> | md_index
<uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]] {state [enable |
disable] | ccm [enable | disable] | pdu_priority <int 0-7> | fault_alarm [all | mac_status |
remote_ccm | error_ccm | xcon_ccm | none] | alarm_time <centisecond 250 -1000> |
alarm_reset_time <centisecond 250-1000>}(1)
Parameters
mepname - Specify the MEP name.
<string 32> - Enter the MEP name used here. This name can be up to 32 characters long.
mepid - Specify the MEP ID.
<int 1-8191> - Enter the MEP ID used here. This value must be between 1 and 8191.
md - Specify the maintenance domain name.
<string 22> - Enter the maintenance domain name used here. This name can be up to 22
characters long.
md_index - Specify the maintenance domain index.
<uint 1-4294967295> - Enter the maintenance domain index value here. This value
must be between 1 and 4294967295.
ma - Specify the maintenance association name.
<string 22> - Enter the maintenance association name used here. This name can be up to
22 characters long.
ma_index - Specify the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value here. This value
must be between 1 and 4294967295.
state - Specify the MEP administrative state.
enable - Specify that the MEP will be enabled.
disable - Specify that the MEP will be disabled. This is the default value.
ccm - Specify the CCM transmission state.
enable - Specify that the CCM transmission will be enabled.
disable - Specify that the CCM transmission will be disabled. This is the default value.