DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
643
Chapter 62
Peripherals Command List
show device_status
show environment
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
config temperature [trap | log] state [enable | disable]
show device_status 62-1
Description
This command is used to display current status of power(s) and fan(s) on the system.
Within fan(s) status display, for example, there are three fans on the left of the Switch, if three fans
is working normally, there will display “OK” in the Left Fan field. If some fans work failed, such as
fan 1,3 , there will only display the failed fans in the Left Fan field, such as “1,3 Fail”.
In the same way, the Right Fan, Back Fan is same to Left Fan. Because there is only one CPU
Fan, if it is working failed, display “Fail”, otherwise display “OK”.
Format
show device_status
Parameters
None.
Restrictions
None.
Example
To show device status:
DGS-3000-26TC:admin#show device_status
Command: show device_status
Internal Power: OK
External Power: None
Right Fan : OK
DGS-3000-26TC:admin#
show environment 62-2
Description
This command is used to display the power and temperature status of the system.

Table of Contents