DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
644
Format
show environment
Parameters
None.
Restrictions
None.
Example
To display the device environment:
DGS-3000-26TC:admin#show environment
Command: show environment
Temperature Trap State : Enabled
Temperature Log State : Enabled
Internal Power : Active
External Power : None
Current Temperature(Celsius) : 32
High Warning Temperature Threshold(Celsius) : 79
Low Warning Temperature Threshold(Celsius) : 11
DGS-3000-26TC:admin#
config temperature threshold 62-3
Description
This command is used to configure the warning threshold for high and low temperature.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
Parameters
high - (Optional) Specify to configure high threshold value. The high threshold must bigger than
the low threshold.
<temperature -500-500> - Enter the high threshold temperature.
low - (Optional) Specify to configure low threshold value.
<temperature -500-500> - Enter the low threshold temperature.
Restrictions
Only Administrators and Operators can issue this command.