DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
833
DGS-3000-26TC:admin#traceroute 10.48.74.121 probe 3
Command: traceroute 10.48.74.121 probe 3
1 <10 ms. 10.12.73.254
2 <10 ms. 10.19.68.1
3 <10 ms. 10.48.74.121
Trace complete.
DGS-3000-26TC:admin#
traceroute6 88-2
Description
This command is used to trace the IPv6 routed path between the Switch and a destination end
station.
Format
traceroute6 [<ipv6addr> | <domain_name 255>] {ttl <value 1-60> | port <value 30000-64900>
| timeout <sec 1-65535> | probe <value 1-9>}
Parameters
<ipv6addr> - Enter the IPv6 address of the destination end station.
<domain_name 255> - Enter the domain name of the destination end station.
ttl - (Optional) The time to live value of the trace route request. This is the maximum number of
routers that a trace route packet can pass. The traceroute command will cross while seeking
the network path between two devices. The range for the TTL is 1 to 60 hops.
<value 1-60> - Enter the time to live value here. This value must be between 1 and 60.
port - (Optional) The port number. The value range is from 30000 to 64900.
<value 30000-64900> - Enter the port number here. This value must be between 30000 and
64900.
timeout - (Optional) Specify the timeout period while waiting for a response from the remote
device. A value of 1 to 65535 seconds can be specified. The default is 5 seconds.
<sec 1-65535> - Enter the timeout period value here. This value must be between 1 and
65535 seconds.
probe - (Optional) The number of probing. The range is from 1 to 9. If unspecified, the default
value is 1.
<value 1-9> - Enter the probing number value here. This value must be between 1 and 9.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To trace the IPv6 routed path between the Switch and 3000::1: