SV-ADAHRS-200/201 Installation and Configuration
SkyView System Installation Guide - Revision AA 5-23
Keep aircraft still (do not move) when pressure is applied.
Steps
1. The aircraft itself should be temperature stable. For example, if the aircraft is moved
from outside in the sun to a hangar for testing, tests should not be started until the
airplane has stabilized at the hangar temperature.
2. Turn SkyView on and let it warm up until the altitude reading is stabilized. This period
should be at least 5 minutes, but may take longer depending on environmental
conditions.
3. Turn SkyView off.
4. While SkyView is off, apply the pressure required by your test to pitot and/or static port
via your test equipment.
5. Turn on SkyView (external or internal battery power is acceptable). Keep aircraft still
while SkyView is powered on. Do not adjust the pitot or static pressures being applied to
the ADAHRS while it is powered on.
6. Verify airspeed and/or altitude reading.
7. Turn SkyView off (using button 1 is a good option for this operation).
8. Repeat steps 4-7 for each required pressure point in the test.
See related procedure:
SV-XPNDR-261/262 Installation and Configuration, Performing Transponder Checks.