25. Appendix E: Serial Data Output
Any of SkyView’s five RS232 serial ports can be configured to output various types of serial data
via SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP. Technical information on the
installation and connection to the serial ports can be found in the Serial Devices section of the
SkyView Installation Guide. To output serial data, you must select either DYNON EMS, ADAHRS,
DYNON SYSTEM, DYNON ADAHRS + SYSTEM, DYNON ADAHRS + EMS, or DYNON ADAHRS + SYS
+ EMS, NMEA OUT (BASIC), or NMEA OUT (FULL) as a Serial Out device, select a baud rate, and
connect the serial port to an external serial device such as a PC. The serial data can be logged
using any standard serial terminal program, a data logger program, or dedicated data logger
device. All numbers are output in decimal except where noted and are standard ASCII. To view
the data using a terminal program, that program should be configured to receive data in the
following format:
Baud rate: Set baud rate to match the baud rate selected on SkyView’s serial port
Data: 8 bit
Parity: none
Stop: 1 bit
Flow control: none
Multiple SkyView display systems: SkyView’s serial ports are designed in a way
that allows serial transmission to continue, uninterrupted, as long as at least one
SkyView display is operational. SkyView accomplishes this by transmitting from
only one display’s serial ports in a multi-display system. SkyView manages which
display is the “actual transmitter” automatically to avoid serial port conflicts.
However, the display that transmits is not user-selectable. Therefore, for reliable
serial reception in multi-display systems, a SkyView serial data output wire must
be wired from each display, in parallel, to the external serial device that is being
used to capture SkyView’s serial data.