SkyView Display Installation and Configuration
4-2 SkyView System Installation Guide - Revision AA
Physical Installation
Display
Panel Cutout
Bezel Outline
SV-D600
6.97” x 5.35”
(177.038mm x 135.890mm)
7.636” x 5.512”
(193.954mm x 140.005mm)
SV-D700
SV-D900
9.68” x 6.90”
(245.872mm x 175.260mm)
10.320” x 7.064”
(262.128mm x 179.426mm)
SV-D1000
SV-D1000T
SV-HDX800
6.97” x 5.35”
(177.04mm x 135.89mm)
7.64” x 5.59”
(194.0 mm x 142.0mm)
SV-HDX1100
9.68” x 6.28”
(245.87mm x 159.50mm)
20.31” x 7.07”
(262mm x 179.5mm)
Table 11 – SkyView Displays Installation Dimensions Quick Overview
If you are converting your panel from a Dynon Avionics EFIS-D100, EMS-D120, or
FlightDEK-D180, note that the SV-D600, SV-D700, and SV-HDX800 displays have a
slightly larger panel cutout than those products and the existing panel cutout for
those products must be slightly enlarged.
Location Requirements for SkyView Displays
Observe the following guidelines when choosing a location for a SkyView display:
SkyView displays require about 2.4” (61mm) of free space behind the panel, depending on
mounting surface thickness.
Consider the ease, or difficulty of disconnecting multiple connectors when removing a SkyView
display from the panel. Plan for either:
o Providing sufficient slack in the cables so that the SkyView display can be removed
from the panel and then the cables disconnected, or…
o Disconnecting (and reconnecting) the cables from behind the panel prior to
removing the SkyView display from the panel.
The SkyView Display Harness (SV-HARNESS-D37) extends about 3” (76mm) from the back of the
display.
Add a 1.0” (25.4 mm), minimum, beyond the physically required volume for the SkyView
display’s heat sinks and fans to operate.
Avoid placing the display near heater vents or any source of extremely hot air.
While SkyView displays do not (normally) require a forced cooling air, if the aircraft
is to be operated in hot climates, the builder should ensure that the stated
operating temperature range for SkyView displays is not exceeded.
The display should be easily viewable without any obstructions.
SkyView Displays have no internal inertial sensors and do not need to be mounted in the same
orientation as the ADAHRS or other modules.

Table of Contents