SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision AA 7-85
Note that oil temperature is configured with a latching alarm in this example. If oil
temperature ever reaches a range configured as red, an alarm will trigger and a
message will show up in the message box on the Main Menu.
EMS Screen Layout Editor
Dynon Avionics offers preconfigured Engine Page layouts that support popular
engine sensor installations. Check our website at
http://downloads.dynonavionics.com.
All sensor mapping, settings, and widget graphical properties are automatically
shared between displays. Installers do not need to transfer files between displays.
Use this wizard to configure the style and layout of the engine and environmental sensor
gauges and calculated parameters (e.g., % power) on the 100%, 50%, 20%, and ENGINE
BOTTOM BAND Engine Pages.
SkyView Classic and SkyView SE cab display 100%, 50%, and 20% pages.
SkyView HDX can display 100%, 50%, and ENGINE BOTTOM BAND pages.
Note that sensors must be defined, mapped, and configured in order to show up on an Engine
Page (reference the EMS Sensor Definitions, Mapping, and Settings Section of this guide for
instructions on how to do this).
To use this tool, enter the wizard (SETUP MENU > EMS SETUP > SCREEN LAYOUT EDITOR), then
choose the page size to edit. Once in the Screen Layout Editor, follow this procedure:
1. Add a sensor or info widget to the screen. Press either SENSOR or INFO to show their
respective menus and scroll through available sensors or info parameters, highlight one,
and then press ACCEPT or move either joystick to the right to add it to the screen.
2. Change the style of the widget. Press STYLE or turn the joystick until the widget’s style is
acceptable.
3. Change the size of the widget. Press SIZE until the widget’s size is acceptable.
4. Change the location of the widget on the screen.
a. In SkyView Classic and SkyView SE, move the CURSR joystick in up, down, right,
and left directions until the location is acceptable. Hold the joystick in those
movement positions for accelerated widget movement.
b. In SkyView HDX, use the Left knob for movement of the widget to Left
(Counterclockwise) and Right (Clockwise). Use the Right knob for movement of
the widget Up (Counterclockwise), and Down (Clockwise).
5. Repeat the above steps for all sensors that you want displayed on the Engine Page.
6. Save the page by pressing SAVE.