Appendix E: Serial Data Output
SkyView HDX System Installation Manual - Revision E 27-9
GP Inputs
The output for GP input pins is:
• Each output is in the format +YYYYZ
o + is the +/- sign for the value
o YYYY is the value of the signal
o Z is the units for the signal
▪ C if the signal is in temperature, and the units are 1/10th degrees C
• YYYY is 1/10th degrees C, so 1234 = 123.4 C
• XXXX if the signal is out of range (red X on ems page)
• ZZZZ if the input is not configured
▪ P if the signal is in pressure, and the units are 1/10 PSI
• YYYY is 1/10th PSI, so 0123 = 12.3 PSI
• XXXX if the signal is out of range (red X on ems page)
• ZZZZ if the input is not configured
▪ G if the signal is in volume, and the units are 1/10th Gallons
• YYYY is 1/10th gallons, so 0183 = 18.3 Gallons
• XXXX if the signal is out of range or not calibrated (red X on ems
page)
• ZZZZ if the input is not configured
▪ V if the signal is in volts (contact input)
• YYYY is 1/100th volts, so 3852 = 38.52V
• ZZZZ if the input is not configured
▪ T if the signal is position
• If elevator, rudder, and aileron trim, YYYY is percent travel, so 0047
= 47%
• If flaps, this is the angle shown on the screen, so 0038 = 38
degrees
• XXXX if the signal is out of range or not calibrated (red X on ems
page)
• ZZZZ if the input is not configured