SkyView HDX Display Installation and Configuration
SkyView HDX System Installation Manual - Revision E 4-21
• On the TY91, configure the serial port appropriately (per Trig’s documentation).
On SkyView
• SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP > SERIAL PORT
x SETUP > SERIAL IN DEVICE > TRIG TY91. This will automatically set the
SERIAL IN FUNCTION, SERIAL IN/OUT BAUD RATE, and SERIAL OUT
DEVICE.
• SETUP MENU > SYSTEM SETUP > PRIMARY COM > TRIG TY91 (PORT x).
• SETUP MENU > SYSTEM SETUP > DISPLAY COM IN TOP BAR > YES.
4.3.9.13 Icom IC-A210 TSO COM Radio
The IC-A210 does not transmit status or frequencies via serial port, so IC-A210
information cannot be displayed on the top bar of the SkyView display(s). SkyView can
send COM radio frequencies to the IC-A210 (TUNE COM).
• Confirm that your A210 is running Software version 1.53 or newer. This feature
will not work with old Software. Contact Icom for details on upgrading your radio
Software.
• Connect IC-A210 serial RX (Molex Pin 2 / D15 Pin 10) to a SkyView serial TX.
If you have more than one (1) SkyView display, make the same connection to
all SkyView displays.
• Ensure there is a shared ground between the SkyView display and the IC-
A210. If you have more than one (1) SkyView display, make the same
connection to all SkyView displays.
• On the IC-A210, configure the serial port appropriately (per Icom
documentation).
On SkyView
• SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP > SERIAL PORT
x SETUP > SERIAL IN DEVICE > ICOM A210. This will automatically set the
SERIAL IN FUNCTION, SERIAL IN/OUT BAUD RATE, and SERIAL OUT
DEVICE. (Although there is no IC-A210 serial TX to SkyView serial RX
connection, SERIAL IN DEVICE must be configured as described.).
• SETUP MENU > SYSTEM SETUP > PRIMARY COM > ICOM A210 (PORT x)
and SETUP MENU > SYSTEM SETUP > DISPLAY COM IN TOP BAR > NO.
4.3.9.14 Garmin GTR 200, GTR 225 COM Radio, GNC 255 COM Radio / NAV
Receiver
SkyView can send frequencies to the GNC 255’s standby frequency.
On the GNC 255:
• Connect GNC 255 P2001 Pin 16 to a SkyView serial TX. If you have more than
one (1) SkyView display, make the same connection to all SkyView displays.
• Connect GNC 255 P2001 Pin 1 to a SkyView serial RX. If you have more than
one (1) SkyView display, make the same connection to all SkyView displays.