Solution Ultima 844/862/880 Installation Manual
Command 965 - Set Up Domestic Dialling Format
Command 965 has been included to allow the set up of the domestic dialling format a one step
operation. Refer to page 126 for more information on Domestic Dialling Format.
After you enter Installer's Programming Mode, enter command
965 followed by the # button.
The command will automatically set Receiver 1 to domestic reporting and set the following locations
only for Receiver 2. No other locations will be changed when command 965 has been issued.
All domestic telephone numbers are stored in “LOCATION 478 – 525”. For more information on
programming domestic dialling, refer to Setting Up and Programming Domestic Reporting on page
127 for more information.
Location Description Setting
LOCATION 032 Handshake Tone For Receiver 1 1 (Handshake Tone)
LOCATION 033 Transmission Format 4 (Domestic)
LOCATION 034 – 039 Subscriber ID Number 0, 0, 0, 0, 0, 1 (1 Beep)
LOCATION 336 Zone Status Reporting Options 2 (Receiver 2 Only)
LOCATION 345 – 346 Open/Close Reports 11, 12 (Open/Close Reports)
LOCATION 347 Open/Close Reporting Options 2 (Receiver 2 Only)
LOCATION 368 - 370 System Status – Access Denied 6, 7, 12 (Access Denied)
LOCATION 371 System Status Reporting Options 2 (Receiver 2 Only)
LOCATION 372 - 378 Test Reporting Time 0, 0, 0, 0, 7, 1, 0 (Test Reports)
LOCATION 379 Test Reporting Dialler Options 1 (Receiver 1 Only)
Table 49: Command 965 Defaults
As you can see from the table above, the transmission format has automatically been set for domestic
dialling and the Subscriber ID Number has been set for one identification beep. All reports except
zone status reporting and system status reporting have been allocated to Receiver 1 for domestic
dialling.
This means that the zone status reports including zone bypass, zone trouble, sensor watch and alarm
restore codes as well as system status reports including fuse fail, AC fail, low battery and access
denied reports have been allocated to Receiver 2 and will not report unless Receiver 2 has also been
set up to report.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited