118 Solution Ultima 844/862/880 Installation Manual
Disable Factory Default
LOCATION 900 0
This feature prevents the control panel from being manually defaulted via the default button or to
prevent using a programming key to perform an automatic download to the control panel when the
system is disarmed.
A zero programmed into this location will allow defaulting of the control panel. If 15 has been
programmed into this location, defaulting of the control panel will not be permitted and the Installer
Code MUST be used for further programming of the control panel.
If the Installer Code is not known, the control panel will need to be returned to Electronics Design and
Manufacturing Pty Limited. A nominal fee applies for this service.
Electronics Design and Manufacturing Pty Limited does not recommend the use of this feature.
If the option is required to disable the option of being able to default the control panel, a special
procedure has been implemented to eliminate the possibility of accidentally setting this option. The
default button on the PCB must be held down while programming this location.
How To Prevent Manual Defaulting Of The Control Panel
1. Enter Installer’s Programming Mode (i.e.. 1234followed by the #button).
Two beeps will be heard and the data currently programmed in “LOCATION 000” will be
displayed via the hand held programmer or remote codepad.
If you are using a remote codepad, the
STAY and AWAY indicators will begin to flash to
indicate that Installer’s Programming Mode has been accessed.
2. From the hand held programmer or remote codepad, go to "LOCATION 900".
(e.g..
900followed by the #button).
3. Hold down and continue to hold down the DEFAULT button.
The default button will be located at the top of the PCB next to the PROGRAMMING KEY
connecting socket.
4. Program a 15 into "LOCATION 900".
(e.g.. 15followed by the *button).
5. Release the default button.
6. Enter command
960 followed by the # button to exit Installer's Programming Mode.
Two beeps will be heard and the system will return to the disarmed state.
If you are using a remote codepad, the
STAY and AWAY indicators will extinguish to indicate
that the system has returned to the disarmed state.