Zone Information 169
Zone Programming
Each zone contains seven locations that are divided into three groups. The first 3 locations determine
how the zone will operate, the next two locations allow various options for each zone and the last two
locations contain the dialler reporting information of each zone.
Zone Operating Information
Zone Type
This location programs the "Zone Type" required (e.g.. Delay-1, Instant, 24 Hour etc).
Zone Pulse Count
This location sets how many times the zone must trigger within the time specified in the "Zone Pulse
Count Time”.
Zone Pulse Count Time
This parameter sets the time period for the number of times the zone must trigger before activating an
alarm.
Zone Options
Zone Options 1
This location controls the zone (e.g.. Lockout Siren, Silent etc).
Zone Options 2
This location controls the zone (e.g.. Isolate In STAY Mode 1, Forced Arming Allowed etc).
Zone Reporting Information
Zone Report Code
If you wish the control panel to send zone alarm reports, this location should be programmed as 1. If
you do not wish to send zone alarm reports, this location should be programmed as a 0.
Zone Dialler Options
This location is factory default to report only to Receiver 1. You can select each zone to report on
Receiver 1, Receiver 2, both Receiver 1 and Receiver 2, Receiver 2 only when Receiver 1 fails or no
reporting at all. Select the required dialler option from the table below.
Option Description
0
No Report Required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and Receiver 2
8
Receiver 2 Only When Receiver 1 Fails
Table 78: Zone Dialler Options
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC