Codepad Indicators 33
FAULT Indicator
The
FAULT indicator is used to display that the system has detected a fault. Refer to Fault
Descriptions on page 53 for more information on system faults.
Every time a new system fault has been detected (e.g.: FAULT indicator flashing), the codepad will
begin to beep once every minute.
Pressing the
button once will cancel the once a minute beep and acknowledge the fault (e.g.:
FAULT indicator on).
Indicator Definition
On
There Is A System Fault That Needs To Be Rectified
Off
The System Is Normal, There Are No Faults
Flashing
There Is A System Fault Waiting To Be Acknowledged
Flashing
Table 15: FAULT Indicator
Programming Mode
These two indicators will flash when the system has entered either Installers Programming Mode or
when any Master Code Functions are used.
Off Indicator/Zone Sealed
The indicator will illuminate when the system is in the disarmed state or Installer’s
Programming Mode has been entered and will flash when a zone becomes unsealed during the
disarmed state. The indicator will stop flashing when all zones are sealed.
On Indicator/Zone In Alarm
The indicator will illuminate when the system is armed in
AWAY Mode and will flash when an
alarm occurs. The indicator will reset once a valid user code has been entered.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC