System Operations 43
Method Two
How To Arm The System In STAY Mode 1
1. Hold down the button until two beeps are heard.
The
STAY indicator will illuminate and exit time will now commence.
Any zones that have been programmed to be automatically isolated in STAY Mode 1 will
begin to flash until exit time expires. At the end of exit time, the
ZONE indicators will
extinguish and the codepad will give one short beep.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will be
constantly illuminated on the remote codepad. The zone will again become an active part of the
system as soon as it has resealed (i.e.. If a window is left open after exit time has expired, the window
will not be an active part of the system until it has closed. Opening the window after exit time has
expired will cause an alarm condition).
Forced Arming
The feature of arming the system when a zone is not sealed is known as forced arming. Refer to Zone
Options 2 on page 179 to enable forced arming for each zone.
If the
STAY indicator does not illuminate and a long beep is heard when attempting to arm the system
in STAY Mode 1, forced arming is not permitted. If this is the case, you must ensure that all zones
are sealed or manually isolated before you can arm the system.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC