Reserved
24 Hour Medical
A 24-Hour Medical zone (Contact ID Event Code 100) is always ready to trigger the dialler, horn
speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A medical
report will be sent to the base station receiver. A 24-Hour Medical zone will not send a restore report
until the zone actually restores.
24 Hour Panic
A 24-Hour Panic zone (Contact ID Event Code 120) is always ready to trigger the dialler, horn
speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A panic
report will be sent to the base station receiver. A 24-Hour Panic zone will not send a restore report
until the zone actually restores.
24 Hour Hold-Up
A 24-Hour Hold-Up zone (Contact ID Event Code 122) is always ready to trigger the dialler, horn
speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. If you
require the hold-up alarm to be silent, enable Option 4 – Silent Alarm in Zone Options 1 on page 175.
A 24-Hour Hold-Up zone will not send a restore report until the zone actually restores.
24 Hour Tamper
A 24-Hour Tamper zone (Contact ID Event Code 137) is always ready to trigger the dialler, horn
speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A 24-Hour
Tamper zone will not send a restore report until the zone actually restores.
Reserved
Keyswitch Zone
A Keyswitch zone is used when you need to connect a keyswitch to operate the system. Refer to
Keyswitch Zone Options on page 177 for selecting options such as momentary, toggle etc. User code
number 16 will be reported when arming and disarming using this method of operation. Programming
the polarity level of user code 16 will also effect the operation of the keyswitch zone. Refer to User
Code Priority on page 161 for more information.
24 Hour Burglary Zone
A 24-Hour Burglary zone (Contact ID Event Code 133) is always ready to trigger the dialler, horn
speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A 24-
Hour Burglary zone will not send a restore report until the zone actually restores.
24 Hour Fire Zone
A 24-Hour Fire zone (Contact ID Event Code 110) is always ready to trigger the dialler, horn speaker,
bell and strobe regardless of whether the system is in the armed or disarmed state. A distinct fire
sound is emitted through the horn speaker to indicate this type of alarm condition. This fire sound is
completely different to the burglary sound. A 24-Hour Fire zone will not send a restore report until
the zone actually restores.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited