180 Solution Ultima 844/862/880 Installation Manual
Zone Reporting Information
Zone Report Code
If you wish the control panel to send zone alarm reports, this location should be programmed as 1. If
you do not wish to send zone alarm reports, this location should be programmed as a 0.
Zone Dialler Options
This location is factory default to report only to Receiver 1. You can select each zone to report on
Receiver 1, Receiver 2, both Receiver 1 and Receiver 2, Receiver 2 only when Receiver 1 fails or no
reporting at all. Select the required dialler option from the table below.
Option Description
0
No Report Required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and Receiver 2
8
Receiver 2 Only When Receiver 1 Fails
Table 85: Zone Dialler Options
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited