User Codes 161
User Code Priority
There are ten different priority levels that can be allocated to the user code. Each priority level allows
or restricts the functions that different user code holders may perform and can only be changed by the
installer.
0
1
2
3
Once user code priority levels 4, 6, 12 or 14 have been programmed to any of the available user
codes, the method of standard isolating will no longer operate. Only those user codes with the
priority level of 4, 6, 12 or 14 will be able to isolate zones using the method code to isolate.
Priority Description Priority Description
0
Arm/Disarm
6
Arm/Disarm + Code To Isolate + Open/Close
Report
1
Arm Only
8
Arm/Disarm + Master Code Functions
2
Arm/Disarm + Open/Close Report
10
Arm/Disarm + Master Code Functions +
Open/Close Report
3
Arm Only + Close Report
12
Arm/Disarm + Master Code Functions + Code To
Isolate
4
Arm/Disarm + Code To Isolate
14
Arm/Disarm + Master Code Functions + Code To
Isolate + Open/Close Report
Table 75: User Code Priority Levels
Arm and Disarm
This priority level allows the user code holder to arm and disarm the system. No opening or closing
reports will be sent when this user code has been used to arm or disarm the system. However, a user
code with this priority level will only send a closing report only after a previous code that has the
ability to send an opening report has disarmed the system.
Arm Only
This priority level allows the user code holder to arm the system but not disarm it. No closing reports
will be sent when this user code has been used to arm the system. However, a user code with this
priority level will only send a closing report only after a previous code that has the ability to send an
opening report has disarmed the system.
Arm and Disarm + Open/Close Reports
This priority level allows the user code holder to arm and disarm the system. When this user code has
been used, an opening or closing report will always be sent along with the user number that armed or
disarmed the system.
This option requires Open/Close reports in “LOCATION 345 - 346” to be enabled on page 189 for it
to be effective.
Arm Only + Closing Reports
This priority level allows the user code holder to arm the system but not disarm it. When this user
code has been used, a closing report will always be sent along with the user number that armed the
system.
This option requires Open/Close reports in “LOCATION 345 - 346” to be enabled on page 189 for it
to be effective.
Electronics Design and Manufacturing Pty Limited ISSUE162.DOC