22
Solution Ultima 844/862/880 Installation Manual
Quick Start
The following steps will allow you to use the Solution Ultima 844/862/880 control panel
with the factory default values. The default values allow the control panel to communicate in the
Contact ID format. If you are not familiar to programming the
Solution range of control panels, we
suggest that you first read information contained in the programming section beginning on page 102.
1. After all wiring has been completed, connect the AC plug pack to the control panel.
Both the
MAINS and AWAY indicators will illuminate. The MAINS indicator will display to
indicate that the AC mains supply has been connected. The
AWAY indicator displays that the
system is now armed in the AWAY Mode. If any 24-hour zones are unsealed at the time the
system is powered up, the siren, strobe and bell outputs will activate into alarm and the
corresponding zone indicator will flash.
2. Enter the default Master Code
2580 followed by the button to disarm the system
and to reset any alarm that may have occurred during the system power up. The
AWAY
indicator will extinguish to indicate that the system has now been disarmed. If any zone
indicators are flashing, this would indicate that an alarm had occurred on that zone. If a zone
indicator is constantly illuminated, this would indicate that the zone is unsealed.
3. The back-up battery should now be connected.
4. Enter the factory default Installer Code 1234 followed by the button. Two beeps
will be heard and the
STAY and AWAY indicators will now flash simultaneously to indicate that
you have now entered Installer’s Programming Mode. When entering Installer’s Programming
Mode, you will be automatically positioned at “LOCATION 000”, the beginning of the
Primary Telephone Number For Receiver 1.
5. Enter the Primary Telephone Number followed by the Secondary Telephone Number and the
Subscriber ID Number for Receiver 1. Refer to Dialler Information on page 138 for more
information.
Remember that when programming a zero in the telephone numbers of Receiver 1 and
Receiver 2, a zero must be programmed as a ten. Programming a zero in the telephone number
will indicate the end of the dialling sequence. A zero must be programmed as a zero in all
locations other than the telephone numbers for Receiver 1, Receiver 2 and the Call Back
Telephone number, unless otherwise stated.
6. Set the time for the test reports if required. Any other programming changes required may also
be made, otherwise the factory default settings will be used. Refer to Test Reporting Time on
page 197 for more information on programming test reports.
7. Enter Installer’s Command
960 followed by the button to exit Installer’s
Programming Mode. Two beeps will be heard and the
STAY and AWAY indicators will
extinguish. The system has now returned to the disarmed state and is now ready for use. Refer
to Installer’s Programming Commands on page 107 for more information.
8. Use the Master Code to set the date and time. Refer to How To Set The Date and Time on
page 23 for more information.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited