162 Solution Ultima 844/862/880 Installation Manual
4
6
8
10
12
14
Arm and Disarm + Code To Isolate
This priority level allows the user code holder to arm and disarm the system. No opening or closing
reports will be sent when this user code has been used to arm or disarm the system. However, a user
code with this priority level will only send a closing report after a previous code that has the ability to
send an opening report has disarmed the system.
Isolating zones will only be allowed by using the method “Code To Isolate” once this priority level
has been set. Refer to Isolating Zones on page 48 for further information.
Arm and Disarm + Code To Isolate + Open/Close Reports
This priority level allows the user code holder to arm and disarm the system. Opening and closing
reports will always be sent when this user code has been used to arm or disarm the system. Isolating
of zones will only be allowed by using the method “Code To Isolate” once this priority level has been
set.
This option requires Open/Close reports in “LOCATION 345 - 346” to be enabled on page 189 for it
to be effective. Refer to Isolating Zones on page 48 for more information.
Arm and Disarm + Master Code Functions
This priority level allows arming and disarming of the system and the ability to carry out any of the
Master Code Functions described on page 76. No opening or closing reports will be sent when this
user code has been used to arm or disarm the system. However, a user code with this priority level
will only send a closing report after a previous code that has the ability to send an opening report has
disarmed the system.
Arm and Disarm + Master Code Functions + Open/Close Reports
This priority level allows arming and disarming of the system and the ability to carry out any of the
Master Code Functions described on page 76. Opening and closing reports will always be sent when
this user code has been used to arm or disarm the system.
This option requires Open/Close reports in “LOCATION 345 - 346” to be enabled on page 189 for it
to be effective.
Arm and Disarm + Master Code Functions + Code To Isolate
This priority level allows arming and disarming of the system and the ability to carry out any of the
Master Code Functions described on page 76. No opening and closing reports will be sent when this
user code has been used to arm or disarm the system. However, a user code with this priority level
will only send a closing report after a previous code that has the ability to send an opening report has
disarmed the system.
Isolating zones will only be allowed by using the method “Code To Isolate” once this priority level
has been set. Refer to Isolating Zones on page 48 for more information.
Arm and Disarm + Master Code Functions + Code To Isolate + Open/Close
Reports
This priority level allows arming and disarming of the system and the ability to carry out any of the
Master Code Functions described on page 76. Opening and closing reports will always be sent when
this user code has been used to arm or disarm the system. This option requires Open/Close reports in
“LOCATION 345 - 346” to be enabled on page 189 for it to be effective. Refer to Isolating Zones on
page 48 for more information.
Isolating zones will only be allowed by using the method Code To Isolate once this priority level has
been set.
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited